logo
Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Programmable Rotary Indexer
Created with Pixso.

DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications

DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications

Brand Name: HONEPAN
Model Number: DS\DF\DA\DT\DFH\DFS\BT\DB\P\HBY\HBYS
MOQ: ≥1000 $
Price: 200 $/SET~4500 $/SET
Packaging Details: PLYWOOD BOX
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Certification:
ISO9001
POSITIONAL ACCURACY:
±30 Arcse (±15 Arcse)
REPOSITIONING ACCURACY:
±4 Arcse(±2 Arcse)
Cam Material:
Default 42CrMoAl,Customizable
Hardness:
50HRC~72HRC ,Customizable
COLOUR:
DEFAULT GRAY (CUSTOMIZABLE)
Dimensions:
Customizable
Warranty:
1year
Longest Lifespan:
60000 Hours
Supply Ability:
5000 SET/MONTH
Highlight:

DE Series Free Stop Cam Indexer

,

Flange Type Cam Indexing Gears

,

Pharmaceutical Field Mandrel Flange Divider

Product Description
DE/DFS Series Free Stop Cam Indexer
Arbitrary Stop Cam Indexing Gears

The DE series mandrel flange divider combines the optimal characteristics of both flange type dividers and mandrel type cam indexers. This versatile indexing solution is engineered for precision performance in demanding industrial applications.

Key Applications

Specifically designed for high-precision production environments, the DE/DFS Series excels in:

  • Pharmaceutical manufacturing systems
  • Liquid filling and packaging lines
  • Automated assembly processes
  • Precision indexing applications requiring free-stop capability

According to the distance between the input shaft and the output shaft, the size of the cabinet, and the size of the load that can be withstood, it can be divided into: 45DE/60DE/70DE/80DE/100DE/110DE/125DE/140DE/150DE/180DE/200DE/250DE

45DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 128
Allowable Axial Load of Output Shaft C2 kgf 138
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 83
Maximum Bending Moment of Input Shaft C4 kgf 108
Maximum Torque of Input Shaft C5 kgf-m 3.8
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 3.2×10-4
Positioning Indexing Accuracy
sec. ±30
Weight
kg 9
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 0
60DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 138
Allowable Axial Load of Output Shaft C2 kgf 140
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 97
Maximum Bending Moment of Input Shaft C4 kgf 148
Maximum Torque of Input Shaft C5 kgf-m 5.8
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 1.9×10-3
Positioning Indexing Accuracy
sec. ±30
Weight
kg 15
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 1
70DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 218
Allowable Axial Load of Output Shaft C2 kgf 298
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 146
Maximum Bending Moment of Input Shaft C4 kgf 105
Maximum Torque of Input Shaft C5 kgf-m 9
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 6×10-3
Positioning Indexing Accuracy
sec. ±30
Weight
kg 20
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 2
80DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 327
Allowable Axial Load of Output Shaft C2 kgf 417
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 345
Maximum Bending Moment of Input Shaft C4 kgf 255
Maximum Torque of Input Shaft C5 kgf-m 24
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 9×10-3
Positioning Indexing Accuracy
sec. ±30
Weight
kg 35
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 3
100DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 500
Allowable Axial Load of Output Shaft C2 kgf 650
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 400
Maximum Bending Moment of Input Shaft C4 kgf 395
Maximum Torque of Input Shaft C5 kgf-m 34
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 4×10-3
Positioning Indexing Accuracy
sec. ±30
Weight
kg 55
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 4
110DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 555
Allowable Axial Load of Output Shaft C2 kgf 695
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 475
Maximum Bending Moment of Input Shaft C4 kgf 410
Maximum Torque of Input Shaft C5 kgf-m 39
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 2.8×10-2
Positioning Indexing Accuracy
sec. ±30
Weight
kg 68
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 5
125DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 630
Allowable Axial Load of Output Shaft C2 kgf 850
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 520
Maximum Bending Moment of Input Shaft C4 kgf 560
Maximum Torque of Input Shaft C5 kgf-m 65
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 0.28
Positioning Indexing Accuracy
sec. ±30
Weight
kg 78
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 6
140DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 755
Allowable Axial Load of Output Shaft C2 kgf 995
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 545
Maximum Bending Moment of Input Shaft C4 kgf 705
Maximum Torque of Input Shaft C5 kgf-m 98
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 0.11
Positioning Indexing Accuracy
sec. ±30
Weight
kg 92
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 7
150DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 760
Allowable Axial Load of Output Shaft C2 kgf 1000
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 550
Maximum Bending Moment of Input Shaft C4 kgf 710
Maximum Torque of Input Shaft C5 kgf-m 100
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 0.11
Positioning Indexing Accuracy
sec. ±30
Weight
kg 94
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 8
180DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 1195
Allowable Axial Load of Output Shaft C2 kgf 1495
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 1095
Maximum Bending Moment of Input Shaft C4 kgf 1955
Maximum Torque of Input Shaft C5 kgf-m 336
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 0.39
Positioning Indexing Accuracy
sec. ±30
Weight
kg 225
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 9
200DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 1210
Allowable Axial Load of Output Shaft C2 kgf 1510
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 1105
Maximum Bending Moment of Input Shaft C4 kgf 1965
Maximum Torque of Input Shaft C5 kgf-m 341
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 0.39
Positioning Indexing Accuracy
sec. ±30
Weight
kg 240
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 10
250DE
Item Symbol Unit Value
Allowable Radial Load of Output Shaft C1 kgf 3195
Allowable Axial Load of Output Shaft C2 kgf 4145
Allowable Torque of Output Shaft Ts kgf-m Refer to Torque Table
Allowable Radial Load of Input Shaft C3 kgf 1545
Maximum Bending Moment of Input Shaft C4 kgf 3795
Maximum Torque of Input Shaft C5 kgf-m 775
Moment of Inertia of Input Shaft (Note 1) C6 kgf-m2 1.98
Positioning Indexing Accuracy
sec. ±30
Weight
kg 695
DE Series Free Stop Cam Indexer with Flange Type Design for Pharmaceutical Field Applications 11